상품상세정보 상품후기 상품QNA 배송교환관련 대현계측기(주) - METERMALL [EXTECH ESA-150] AC/DC내전압시험기 / 절연저항 / 접지도통 / 누설전류 / AC파워소스
열화상카메라 전력분석기 배너1 배너2 배너3 배너4 배너5 중앙롤링상품 타이틀배너 중앙작은배너 01 중앙작은배너 02 중앙이벤트배너 하단이벤트배너 01 하단이벤트배너 02 배송조회 가입하러가기 적립금확인하기 inicis 핀터레스트 페이스북 트위터 카카오 정품보장

커뮤니티 리스트

  • 온라인 견적문의
  • 검교정
  • 주문/배송조회
  • 고객만족센터
  • 무통장입금안내
[EXTECH ESA-150] AC/DC내전압시험기 / 절연저항 / 접지도통 / 누설전류 / AC파워소스
판매가격 : 전화문의
제품코드 : ESA-150
제조사 : EXTECH(익스텍)
브랜드 : EXTECH(익스텍) [브랜드바로가기]
구매수량

 
 
ESA Electrical Safety Compliance Analyzer는 ACW, DCW, IR, Ground Bond, Touch Current, RUN TEST, 내장 AC 소스를 갖춘 7-in-1 Electrical Safety Compliance Analyzer 입니다.
 
특징
 
7-in-1 Electrical Safety Compliance Analyzer (ACW,DCW,IR,GB,TC,RUN TEST and AC Source)
Enhanced 7 inches TFT-LCD display (800 x 480)
DSP Technology precision and high speed measurement smooth 15 and user interface and quick responses responses
With Quick Access Menu “My Menu” feature
DualCHEK simultaneous Ground Bond and Hipot
Phase Lock function for “Hot” Hipot Tests
Optional Built-In 500VA Programmable AC Power source
MD Voltage Display for measuring the voltage drop across the measuring device
I-Max Leakage Current Display to record maximum leakage current detected during an LLT.
AC, DC, AC+DC Leakage Current Display Capability in LLT. (option)
MD circuits with BNC port
External Output Channel with HV
New memory set up, allowing for flexibility in step and memory numbers. Total up to 10,000 memories or steps
Multinational selection English language user interface selection. / Traditional / Chinese / Simplified Chinese
Standard USB & RS232 PC Control Card, Optional Ethernet, GPIB, Multi-function Interface card
Advanced security with User ID and Password protection
Auto detection 115Vac or 230Vac input voltage
Exclusive DC Hipot force discharge (Pat.#M279103)
Exclusive Smart GFI Circuit (Pat.#169000)
Ramp High feature (Pat.#100859)
Charge Low feature (Pat.#106128)

 

 

 

 

 

ESA Series TFT-LCD Electrical Safety Compliance Analyzer

 

MODEL ESA-140 ESA-150
AC WITHSTAND VOLTAGE
Output Rating 5KVAC / 50mA 5KVAC / 100mA
Range Range Resolution Accuracy
Output Voltage, ACV 0 - 5000 1 ± (2% of setting + 5V)
Output Frequency 50Hz / 60Hz ±0.1%, User Selection
Output Waveform Sine Wave, Crest Factor = 1.3 - 1.5
Output Regulation ± (1% of output + 5V), From no load to full load and Low Line to High Line (combined regulation)
SETTINGS
HI and LO-Limit (Total) current, mA 0.000 - 9.999 0.001 ± (2% of setting + 2 counts)
10.00 - 50.00 (for ESA-140) 0.01
10.00 - 100.00 (for ESA-150)
HI and LO-Limit (Real) current, mA 0.000 - 9.999 0.01 ± (3% of setting + 50μA)
10.00 - 50.00 (for ESA-140) 0.1
10.00 - 99.99 (for ESA-150)
Ramp - Up Timer, second 0.1 - 999.9 0.1 ± (0.1% of setting + 0.05 sec)
Ramp - Down Timer, second 0.0 - 999.9
Dwell Timer, second 0, 0.4 - 999.9
(0 = continuous)
Ground Continuity Current: DC 0.1 A ± 0.01A, fixed
Max. Ground Resistance: 1.0 Ω ± 0.1Ω
Current Offset 0.000 - 50.00mA (PF=0.00 - 1.00)* (Total current + current offset ≤50mA) for ESA-140
0.000 - 99.99mA (PF=0.00 - 1.00)* (Total current + current offset ≤100mA) for ESA-150
Arc Detection 1 - 9 ranges (9 is the most sensitivity)
DC WITHSTAND VOLTAGE
Output Voltage, DCV 0 - 6000 1 ± (2% of setting + 5V)
DC Output Ripple < 4% (6KV/20mA at Resistive Load)
SETTINGS
HI and LO - Limit current, μA 0.0 - 999.9 0.1 ± (2% of setting + 2 counts)
1000 - 20000 1
Ramp - Up Timer, second 0.4 - 999.9 0.1 ± (0.1% of setting + 0.05 sec)
Ramp - Down Timer, second 0.0, 1.0 - 999.9
Dwell Timer, second 0, 0.3 - 999.9
(0 = continuous)
Ramp - HI current > 20 mA peak maximum, ON / OFF User Selection
Charge - LO current 0.0 - 350.0 μA DC or Auto Set
Discharge Time < 10mSec
Maximum Capacitive Load
DC Mode
1μF < 1KV 0.08μF < 4KV
0.75μF < 2KV 0.04μF < 5KV
0.5μF < 3KV
Ground Continuity Current: DC 0.1 A ± 0.01A, fixed
Max. Ground Resistance: 1.0 Ω ± 0.1Ω
Arc Detection 1 - 9 ranges (9 is the most sensitivity)
INSULATION RESISTANCE
Output Voltage, DCV 30 - 1000 1 ± (2% of setting + 2 counts)
Charging Current Maximum > 20mApeak
SETTINGS
HI and LO - Limit resistance, MΩ 0.05 - 99.99 (HI - Limit: 0 = OFF) 0.01 0.05 - 999.9, ± (2% of setting + 2 counts)
100.0 - 999.9 0.1 1000 - 9999, ± (5% of setting + 2 counts)
1000 - 50000 1 10000 - 50000, ± (15% of setting + 2 counts)
Ramp - Up Timer, second 0.1 - 999.9 0.1 ± (0.1% of setting + 0.05 sec)
Ramp - Down Timer, second 0.0 , 1.0 - 999.9
Dwell Timer, second 0, 0.5 - 999.9
(0 = continuous)
Delay Timer, second 0.5 - 999.9
Charge - LO current, μA 0.000 - 3.500 or Auto Set
GROUND BOND
Output AC Current, A 1.00 - 40.00 0.01 ± (2 % of setting + 2 counts)
Output Voltage, Vac 3.00 - 8.00 0.01 ± (2 % of setting + 3 counts)
Output Frequency, Hz 50Hz / 60Hz ± 0.1%, User Selection
Output Regulation ± (1% of output + 0.02A), Within maximum load limits, and over input voltage range
Maximum Loading 1.00 - 10.00A / 0 - 600mΩ, 10.01 - 30.00A / 0 - 200mΩ, 30.01 - 40.00A / 0 - 150mΩ
SETTINGS
Lead Resistance Offset, mΩ 0 - 200 1 ± (2% of setting + 2 counts )
HI and LO - Limit Resistance, mΩ 0 - 150 (30.01 - 40.00A) 1 6.00 - 40A, ± (2% of setting + 2 counts )
0 - 200 (10.01 - 30.00A)
0 - 600 (6.00 - 10.00A)
0 - 600 (1.00 - 5.99A) 1.00 - 5.99A, ± (3% of setting + 3 counts )
Dwell Timer, second 0, 0.5 - 999.9
(0 = continuous)
0.1 ± (0.1% of setting + 0.05 sec)
CONTINUITY TEST
Output Current 0.1A for 0 - 10.00Ω, 0.01A for 10.1 - 100.0Ω, 0.001A for 101 - 1000Ω, 0.0001A for 1001 - 10000, 0.1A is Max.
SETTINGS
Max and Min - Limit Resistance ,Ω 0.00 - 10.00 0.01 ± (1% of setting + 3 counts)
10.1 - 100.0 0.1
101 - 1000 1
1001 - 10000 1 ± (1% of setting + 10 counts)
Dwell Timer, second 0.0, 0.3 - 999.9
(0 = continuous)
0.1 ± (0.1% of setting + 0.05 sec)
Resistance Offset, Ω 0.00 - 10.00 0.01 ± (1 % of reading + 3 counts)
MEASUREMENT
  Range Resolution Accuracy
Voltage, KV (AC / DC) 0.00 - 6.00 0.01 ± (2 % of reading +1 count)
Voltage, Vdc (IR only) 0 - 1000 1 ± (2 % of reading + 2 counts)
AC Current (Total), mA 0.000 - 3.500 0.001 ± (2% of reading + 2 counts)
3.00 - 100.00 0.01
AC Current (Real), mA 0.000 - 9.999 0.001 ± (3% of reading + 50μA)
All Ranges PF > 0.1, V > 250VAC
10.00 - 99.99 0.01
DC Current, μA 0.0 - 350.0 0.1 ± (2% of reading + 2 counts)
DC Current, mA 0.300 - 3.500 0.001
3.00 - 20.00 0.01
AC Current, A (GB) 0.00 - 40.00 0.01 ± (3 % of reading + 3 counts)
Resistance, MΩ (IR) 30 - 499V 500 - 1000V   30 - 499V
0.05 - 999.9, ± (7% of reading+2 counts)
500 - 1000V
0.05 - 999.9, ±(2% of reading+2 counts)
1000 - 9999, ±(5% of reading+2 counts)
10000 - 50000, ±(15% of reading+2 counts)
0.050 - 1.999 0.050 - 9.999 0.001
2.00 - 19.99 10.00 - 99.99 0.01
20.0 - 199.9 100.0 - 999.9 0.1
200 - 50000 1000 - 50000 1
Resistance, mΩ (GB) 0 - 600 1 1.00 - 2.99 A, ± (3 % of reading + 3 counts)
3.00 - 40.00 A, ± (2 % of reading + 2 counts)
Resistance, Ω (Continuity) 0.00 - 10.00 0.01 ± (1 % of reading + 3 counts)
10.1 - 100.0 0.1
101 - 1000 1
1001 - 10000 1 ± (1 % of reading + 10 counts)
GENERAL
Input Voltage AC 115/230Vac±15% Auto Range, 50/60Hz ± 5%, 5A/250Vac Slow-Blow for ESA-140, 10A/250Vac Slow-Blow for ESA-150
PLC Remote Control Input : Test, Reset, Interlock, Recall File 1 through 3, Recall File 1 through 7(Option)
Output: Pass, Fail, Test-in-Process
Memory 10000 steps, allow the user create different memories and steps
TFT LCD 800 x 480 resolution digital TFT LCD, 9 ranges contrast setting
DualCHEK 5kVac/25mA and 25Aac/150mΩ for ESA-140
5kVac/50mA and 30Aac/150mΩ for ESA-150
Safety Built-in Smart GFI circuit,GFI trip current 5.0mA max., HV shut down speed: <1mS
(on 50/60Hz and test under 1000V)
Hot Hipot Tests To detect the line input voltage to produce a simultaneous sine wave of line power at hipot output
MyMenu This is a menu that would be customizable by the user, allowing them to create a menu of their favorite most used functions and menu selection.
Interface Standard USB & RS232 PC Control Card, Optional Ethernet, GPIB (IEEE-488.2), Multi-function Interface card (USB-A / RS-485 / RS-232 / BAR Code PS / 2 type)
Multinational language The operate screen interface to provide selection different language including English / Traditional Chinese / Simplified Chinese
Alarm Volume Setting Range: 0 - 9 ;0=OFF, 1 is softest volume, 9 is loudest volume.
Calibration Software and adjustments are made through the front panel. Automatic Calibration alert function to signal
operator when re-calibration is due.
Environment 0 - 40ºC, 20 - 80%RH
Dimensions/Net Weight 430mm(W) × 133mm(H) × 500 mm(D) / 30Kg
OPTION
Opt.794 MATRIX SCANNER MODULE
High Voltage Rating 5KVAC/6KVDC
High Current Rating 40 A
Number of HV Channel 8
Number of HA Channel 8
Point to Point Continuity Used the Scanner to reach point to point continuity test and this function is standard feature when built in scanner
Opt.767 RUN TEST MODULE
DUT POWER
AC Voltage 0 - 277.0V, Single phase unblance
Current 16A maximum continuous
Power Rating 4500W maximum
Short Circuit Protection 23Arms or Inrush Current 68Apeak, Response time RMS < 3 sec ; PEAK < 10uS
SETTINGS
HI and LO Limit AC Voltage, V 30.0 - 277.0 0.1 ± (1.5% of setting + 0.2 V)
HI and LO Limit AC Current, A 0.00 - 16.00 0.01 ± (2% of setting + 2 counts)
HI and LO Limit AC Power, W 0 - 4500 1 ± (5% of setting + 3 counts)
HI and LO Limit Power Factor 0.000 - 1.000 0.001 ± (8% of setting + 2 counts)
HI and LO Limit Leakage Current 0.00 - 10.00
Hi - Limit 0 = OFF
0.01 ± (2% of setting + 2 counts)
Delay Time, second 0.2 - 999.9 0.1 ± (0.1% + 0.05 sec)
Dwell Time, second 0, 0.1 - 999.9 (0 = continuous)
MEASUREMENT
  Range Resolution Accuracy
Voltage, Vac 0.0 - 277.0 0.1 ± (1.5% of reading + 2counts) 30 - 277V
Current, Aac 0.00 - 16.00 0.01 ± (2% of reading + 2counts)
Power, Watts 0 - 4500 1 ± (5% of reading + 3 counts)
Power, Factor 0.000 - 1.000 0.001 ± (8% of reading + 2 counts)
Leakage Current, mA 0.00 - 10.00 0.01 ± (2% of reading + 2 counts)
MD Leakage current measuring resistor = 2kΩ ± 1%
Opt.768 TOUCH CURRENT TEST MODULE
DUT
DUT Input Power Rating 0-277V,AC@ 16Aac max
Current 16A maximum continuous
Short Circuit Protection 23Arms or Inrush Current 68Apeak, Response time RMS < 3 sec ; PEAK < 10uS
SETTINGS
Leakage current High/Low Limit (RMS), μA Range 0.0-999.9μA (0=OFF), Resolution 0.1μA
1000~10000uA 1μA
Leakage current High/Low Limit (peak), μA Range 0.0-999.9μA (0=OFF), Resolution 0.1μA
1000~10000uA 1μA
Dwell Time, second 0, 0.7-999.9 (0=continous) 0.1 ± (0.1% + 0.05 sec)
Delay Time, second 0.5-999.9
Compliance Standards A. UL544 Non Patient, UL484, IEC60598, UL1363,UL923, UL471, UL867, UL697
B. UL544 Patient Care
C. UL2601-1, IEC60601-1, EN60601-1
D. UL1563
E. IEC60990 Fig4 U2, IEC 60950-1, IEC60335-1, IEC60598-1, UL484, IEC60065, IEC61010,IEC60065
F. IEC60990 Fig5 U3, IEC60598-1
G. Basic measuring element 1k ohm of frequency check
MD A - G components Accuracy: Resistance ± 1% Capacitance ± 5%
MD Voltage Limit Maximum 30V peak or 30VDC
Probe settings G-L, Ph-Pl, Ph-L (Use HV relay and HV terminal connector)
Internal Leakage 1. Internal Leakage current = 65uA
2. 277V applied to Ph max leakage current = 70uA.
External MD User can add one extra MD for his application.
CURRENT MEASUREMENT The leakage current is fitting range by leakage current Hi-limit setting value
Frequency Range DC, 15Hz≤ F ≤1MHz
Leakage Current Range (RMS)
Auto Range Range 1 - Range 6 0.0uA - 10.00mA Resolution 0.1uA / 1uA / 0.01mA
Fixed Range > 6% of Range Range 1 - Range 6 0.0uA - 10.00mA Resolution 0.1uA / 1uA / 0.01mA
Fixed Range < 6% of Range Range 2 - Range 6 0.0uA - 600uA Resolution 0.1uA / 1uA / 0.01mA
Accuracy For Auto Range
Range Mode Frequency Basic Accuracy
Range 1~5*1 AC+DC DC, ±2% of reading + 3 counts
15Hz < f <100kHz ±2% of reading + 3 counts
100kHz < f < 1MHz ±5% of reading (>10.0uA)
AC only*2 15Hz < f <30Hz ±3% of reading + 5 counts
30Hz < f <100kHz ±2% of reading + 3 counts
100kHz < f < 1MHz ±5% of reading (>10.0uA)
DC only*3 DC ±2% of reading + 3 counts(>10.0uA)
Range 6*1 AC+DC DC, ±5% of reading (>10.0uA)
15Hz < f <100kHz
AC only*2 15Hz < f <30Hz
30Hz < f <100kHz
DC only*3 DC
Accuracy For Fixed Range
Range Mode Frequency Basic Accuracy(>6% of Range) Additional Error(<6% of Range)
Range 1~5*1 AC+DC DC, ±2% of reading + 3 counts add (2% of reading + 0.2% of range)
15Hz < f <100kHz ±2% of reading + 3 counts add (2% of reading + 0.2% of range)
100kHz < f < 1MHz ±5% of reading (>10.0uA) add (2% of reading + 0.5% of range)
AC+DC 15Hz < f <30Hz ±3% of reading + 5 counts add (2% of reading + 0.2% of range)
30Hz < f <100kHz ±2% of reading + 3 counts add (2% of reading + 0.2% of range)
100kHz < f < 1MHz ±5% of reading (>10.0uA) add (2% of reading + 0.5% of range)
DC only*3 DC ±2% of reading + 3 counts(>10.0mV) add (2% of reading + 0.2% of range)
Range 6*1 AC+DC DC, ±5% of reading (>10.0mV) add (2% of reading + 0.2% of range)
15Hz < f <100kHz
AC only*2 15Hz < f <30Hz
30Hz < f <100kHz
DC only*3 DC
Leakage Voltage Range (Peak)
Auto Range Range 1 - Range 6 0.0mV - 15.00V Resolution 0.1mV / 1mV / 0.01V
Fixed Range > 6% of Range Range 1 - Range 6 0.0mV - 15.00V Resolution 0.1mV / 1mV / 0.01V
Fixed Range < 6% of Range Range 2 - Range 6 0.0mV - 900mV Resolution 0.1mV / 1mV / 0.01V
Accuracy For Auto Range
Range Mode Frequency Basic Accuracy
Range 1~5*1 AC+DC DC ±2% of reading + 2mV
15Hz < f < 1MHz ±10% of reading +2mV
AC only*2 15Hz < f < 1MHz ±10% of reading +2mV
Range 6*1 AC+DC DC ±2% of reading + 3 counts
15Hz < f <100kHz ±10% of reading +2 counts
AC only*2 15Hz < f <100kHz ±10% of reading +2 counts
Accuracy For Fixed Range
Range Mode Frequency Basic Accuracy(>6% of Range) Additional Error(<6% of Range)
Range 1~5*1 AC+DC DC, ±2% of reading + 2mV add (2% of reading + 0.2% of range)
15Hz < f <100kHz ±10% of reading + 2mV add (2% of reading + 0.2% of range)
100kHz < f < 1MHz ±10% of reading +2mV add (2% of reading + 0.5% of range)
AC only*2 15Hz < f <100kHz ±10% of reading + 2mV add (2% of reading + 0.2% of range)
100kHz < f < 1MHz ±10% of reading 2mV add (2% of reading + 0.5% of range)
Range 6*1 AC+DC DC, ±2% of reading +3 counts add (2% of reading + 0.2% of range)
15Hz < f <100kHz ±10% of reading +2 counts
AC only*2 15Hz < f <100kHz ±10% of reading +2 counts
To explain with notes for leakage
*1.If the final measured signal is >range 5 then the maximum composite signal that can be measure is 28 volts peak。
If the final measured signal is ≤ range 5 then the maximum composite signal that can be measure is 12 volts peak。
*2.AC cutoff frequency for High Pass Filter is 15Hz on AC only mode。
*3.AC cutoff frequency for Low Pass Filter is 15Hz on DC only mode。
Leakage Imax Range
The specification is as same as leakage current(RMS)
The specification is as same as leakage current(Peak)
LINE VOLTAGE MEASUREMENT
Range 0.0-277.0 VAC
Resolution 0.1 V
Accuracy ± (1.5% of reading +0.2V), 30.0-277.0V
GENERAL
Continous Power Output selection (like Continuous Run) for both TCT and Run testing. To create Continnuous parameter selection for both TCT and RUN testing.When continuous =ON, the power is not shut down between steps .But in the TCT mode, when the steps setting different line condition, DUT output will momentary power off 25ms then power on.
Opt.769 AC SOURCE 500VA
OUTPUT
Power 630VA and 500W Maximum
Voltage 0 - 150.0V / 0 - 277.0V
Current 4.20A / 2.10A